Pharmaceutical
BLS — Bubbles Level Sensor
Air-bleed level sensor for "difficult" liquids. No electrics inside the tank — ATEX-friendly.
- Client
- Textile industry, then also applied in pharmaceuticals
- Year
- 2023
- Project duration
- 12 mesi
01
The challenge
Dirty, aggressive or thickening liquids cannot be measured with conventional sensors (float, capacitive). ATEX zones require zero electrical components inside the tank.
02
The solution
- Level measurement via head pressure: the tube continuously bleeds a small amount of compressed air above 1000 mm H₂O.
- External pressure sensor measures continuously. Configurable min/max thresholds.
- Atmospheric pressure is the natural zero reference — robust calibration.
- Versions with digital outputs (thresholds) or analog level proportional output (BLS-H).
- Control box in safe zone, connected to the tank only by a ø4 mm polyurethane tube. ATEX-compatible.
03
Technologies
Differential pressure sensor ø4 mm polyurethane tube Safe-zone control box Digital + analog outputs ATEX compatible
04
Results
Aggressive liquids
Zero electrical contact
ATEX-safe
Electronics in safe zone
1000 mm H₂O
Measurement range
Got a similar need?